Greenheck-fan 452413 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Ventilateurs Greenheck-fan 452413. Greenheck Fan 452413 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Please record the Serial, Model #, and Mark for the hood and other equipment for future reference.
Serial #: _______________________ Model #: ______________________ Mark: _________________
Serial #: _______________________ Model #: ______________________ Mark: _________________
Serial #: _______________________ Model #: ______________________ Mark: _________________
Serial #: _______________________ Model #: ______________________ Mark: _________________
Serial #: _______________________ Model #: ______________________ Mark: _________________
Serial #: _______________________ Model #: ______________________ Mark: _________________
Serial #: _______________________ Model #: ______________________ Mark: _________________
Serial #: _______________________ Model #: ______________________ Mark: _________________
Serial #: _______________________ Model #: ______________________ Mark: _________________
Serial #: _______________________ Model #: ______________________ Mark: _________________
Serial #: _______________________ Model #: ______________________ Mark: _________________
Installation, Operation and Maintenance Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the
product described. Protect yourself and others by observing all safety information. Failure to comply with instructions
could result in personal injury and/or property damage! Retain instructions for future reference.
®
PN 452413
Canopy Type Kitchen Hoods
1
Canopy Hood
Vue de la page 0
1 2 3 4 5 6 ... 39 40

Résumé du contenu

Page 1 - Canopy Type Kitchen Hoods

Please record the Serial, Model #, and Mark for the hood and other equipment for future reference.Serial #: _______________________ Model #: ___

Page 2 - Table of Contents

10Canopy Hood®• ThesefastenersaretohelpmaintainthelocationoftheBackSupply,andarenotintendedtohold the weight of the Back Supply Uni

Page 3

11Canopy Hood®Before hanging the hood according to the hood installation instructions, please check the following:1. Make sure the back supply plenum

Page 4 - Receiving and Handling

12Canopy Hood®Before installing the enclosure panels, make sure the hood is hung in position with all the ductwork attached and electrical connections

Page 5 - Installation

13Canopy Hood®Fig. 201. After the hood is hung in position, slide the hemmed form on top of the end skirt onto the end panels of the hood.2. Drill a

Page 6 - Hood Hanging Height

14Canopy Hood®Fig. 21Installing Backsplash PanelsMATERIAL GAUGE — STAINLESSMATERIAL GAUGE — STAINLESSINSULATION — 1 IN. (25.4 MM)FLAT BACKSPLASH PANEL

Page 7 - Electrical Connections

15Canopy Hood®1. After the hood is hung in position, slide the flat flange of the backsplash panel behind the back of the hood. Note: If the backspl

Page 8 - Using the Supply Plenum Clip

16Canopy Hood®HOOD SECTION VIEWDEFLECTOR TO BE PLACED CENTEREDUNDER THE SUPPLY DUCT COLLARSUPPLYFIRE DAMPERINTERNALSUPPLYCHAMBERHOODINSULATEDSUPPLY PL

Page 9 - HSP or VSP - Variable Supply

17Canopy Hood®This is a guide to assist in determining if multiple hoods on one fan can be balanced to have equal static pressure. For multiple hoods

Page 10 - Canopy Hood

18Canopy Hood®Baffle Filter Style HoodsA. Exhaust:With all the filters in place, determine the total hood exhaust volume with a rotating vane anemomet

Page 11 - Hanging the Hood

19Canopy Hood®255(4663.44 m/h)248(4535.42 m/h)256(4681.73 m/h)240(4389.12 m/h)250(4572 m/h)Measure the velocity of each location. A digital 2.75 in.

Page 12 - Installing Enclosure Panels

2Canopy Hood®Receiving and Handling ...4Storage ...

Page 13 - Installing End Skirts

20Canopy Hood®B. Supply (If Applicable):Example for Perforated Face Supply1. Hood set up If the make-up air unit has a temperature control, it shoul

Page 14 - INSULATED BACKSPLASH PANEL

21Canopy Hood®14 in.17.25 in.10 in.2.75 in.6 in.2.75 in.14 in.Fig. 32Fig. 33Fig. 34Nominal Filter Size (H x L)ImperialConversion FactorMetricConversio

Page 15 - Installing Backsplash Panels

22Canopy Hood®Rotation VaneAnemometer2 in.Fig. 35Fig. 36Cartridge Filter SizeImperial Conversion FactorMetricConversion Factor16 in. (400 mm) high wit

Page 16 - Installing Duct Collars

23Canopy Hood®1/2 width1/2 heightFig. 38Nominal Filter Size (H x L)ImperialConversion FactorMetricConversion FactorInches Millimeters16 x 16 400 x 400

Page 17 - Checking for Balance

24Canopy Hood®A. ExhaustWith all the filters in place, determine the total hood exhaust volume with a rotating vane anemometer as follows: 1. All coo

Page 18 - Testing Hood Air Volume

25Canopy Hood®14.25 in.2.75 in.2.75 in.2.5 in.3.25 in.14.75 in.14.25 in.2.75 in.2.75 in.Fig. 42Fig. 44Fig. 43Nominal Filter Size (H x L)ImperialConver

Page 19 - (4572 m/h)

26Canopy Hood®Short Circuit HoodsA. SupplyAll cooking equipment should be off. The hood exhaust should also be off.1. Measuring Velocities • Veloci

Page 20 - B. Supply (If Applicable):

27Canopy Hood®POWER SOURCEMANUAL RESET RELAYMICROSWITCHMICROSWITCHELECTRIC GAS VALVEINSTALLER PROVIDED JUNCTION BOXESPRMBASIC WIRING DIAGRAMRED (COMMO

Page 21 - A. Exhaust

28Canopy Hood®Field Wiring for the Ansul Snap-Action SwitchOption ARelay Part No. 14702* K1a and K1b are N.O. when K1 is de-energizedManual Reset Rela

Page 22

29Canopy Hood®HOOD-1BHOOD-1A BASIC WIRING DIAGRAM (WIRING BY OTHERS)FROM MAKE-UP AIRSTARTER #3TO CUBE FANDISCONNECT SWITCHWIRED THROUGHBREATHER TUBE

Page 23

3Canopy Hood®Maintenance ...32Grease Grabber™ Cleaning and Maintenance ...

Page 24

30Canopy Hood®EXHAUST FAN CONTACTSUPPLY FAN CONTACTEXHAUST FAN CONTACTSUPPLY FAN CONTACTSEPARATE EXHAUST & SUPPLY SWITCHINGCOMBINED EXHAUST &

Page 25

31Canopy Hood®ONON (NO)ONON (NO)ONONON (NO)ONON (NO)ONONON (NO)ON (NO)ON ONONON (NC) ON (NC)ONON (NC)ON (NC)ONON (NC)ON (NC)OFFOFFOFFOFFOFFOFFOFFOFFOF

Page 26 - A. Supply

32Canopy Hood®Daily Maintenance1. Wipe grease from exposed metal surfaces on the hood interior using a clean, dry cloth.2. Visually inspect the filt

Page 27 - Amerex Wiring Plan View

33Canopy Hood®NOTE: Never install the Second Stage filter in the front filter channel. The Second Stage filter must be installed behind a UL Classifie

Page 28 - Ansul Wiring Plan View

34Canopy Hood®1A 1B2A 2B3A 3BStep 1 Remove the front GX filters: (1A) Remove middle filters first, (1B) slide ends toward middle and remove.1C2C3CSte

Page 29 - Overall Wiring Plan View

35Canopy Hood®NOTE: Standard cooking will turn the beads yellow in color. Open flame cooking will cause the beads to blacken. Neither affects the perf

Page 30 - Wiring for Hood Switch Panels

36Canopy Hood®TroubleshootingProblem: Exhaust fan is not operating or is not operating at design levels.Is the fan receiving power? Replace fuses, res

Page 31 - Circuit Diagrams

37Canopy Hood®TroubleshootingProblem: Smoke blows away before reaching the bottom of the hood.Are there pass-thru windows near the hood? Adjust amoun

Page 32 - Maintenance

38Canopy Hood®Before calling your manufacturers representative to report a problem have the following information available: 1. Review / summary of

Page 33 - Fig. 55Fig. 54Fig. 53

39Canopy Hood®GREENHECK PART NUMBERREGISTERS452700 24 x 8 Aluminum Single Deflection H-OB452701 36 x 8 Aluminum Single Deflection H-OB452702 36 x 8 Al

Page 34

4Canopy Hood®Upon receiving the equipment, check for both obvious and hidden damage. If damage is found, record all necessary information on the bill

Page 35

40452413 • Canopy Hood, Rev. 7, March 2008 Copyright 2008 © Greenheck Fan Corp.Greenheck warrants this equipment to be free from defects in material

Page 36 - Troubleshooting

5Canopy Hood®NOTE: If you have a Back Supply Plenum (BSP), this must be installed before the hood. Please see Page 10.For Wall/Single Island Style Hoo

Page 37

6Canopy Hood®Before hanging the hoods, please verify the hood marks to make sure the correct hood is hung on the correct side.A double island hood is

Page 38 - Replacement Parts

7Canopy Hood®Note: The installation of the canopy hoods shall be in accordance with NFPA 96 (latest edition), Standard for Ventilation Control & F

Page 39

8Canopy Hood®HOOD STANDING SEAM HANGING CLIP BOLTED TO PLENUM SHELL HANGING CLIP HOOD FRONT "C" CLAMP SUPPLY PLENUM SHELL HANGER BRACKET EN

Page 40 - Warranty

9Canopy Hood®ATTACHED AIR CURTAIN CANOPY STYLE HOOD ATTACHED AIR CURTAIN CANOPY STYLE HOODBACKSUPPLY BACKSHELF HOODBACKSUPPLY CANOPY STYLE HOODBACKSUP

Commentaires sur ces manuels